SWSYNC=0, REINIT=0, SYNCHOM=0, TRIG2=0, CNTMAX=0, TRIG0=0, CNTMIN=0, TRIG1=0
Synchronization
CNTMIN | Minimum Loading Point Enable 0 (0): The minimum loading point is disabled. 1 (1): The minimum loading point is enabled. |
CNTMAX | Maximum Loading Point Enable 0 (0): The maximum loading point is disabled. 1 (1): The maximum loading point is enabled. |
REINIT | FTM Counter Reinitialization By Synchronization (FTM counter synchronization) 0 (0): FTM counter continues to count normally. 1 (1): FTM counter is updated with its initial value when the selected trigger is detected. |
SYNCHOM | Output Mask Synchronization 0 (0): OUTMASK register is updated with the value of its buffer in all rising edges of the system clock. 1 (1): OUTMASK register is updated with the value of its buffer only by the PWM synchronization. |
TRIG0 | PWM Synchronization Hardware Trigger 0 0 (0): Trigger is disabled. 1 (1): Trigger is enabled. |
TRIG1 | PWM Synchronization Hardware Trigger 1 0 (0): Trigger is disabled. 1 (1): Trigger is enabled. |
TRIG2 | PWM Synchronization Hardware Trigger 2 0 (0): Trigger is disabled. 1 (1): Trigger is enabled. |
SWSYNC | PWM Synchronization Software Trigger 0 (0): Software trigger is not selected. 1 (1): Software trigger is selected. |
RESERVED | no description available |